MCS180x Linear Hall-Effect Current Sensors

Monolithic Power Systems (MPS) MCS180x Linear Hall-Effect Current Sensors feature a small footprint that saves board space and is well-suited for space-constrained applications. The series is offered in SOIC-8 packaging with a tape-and-reel option. The MCS180x modules are used for AC and DC current sensing. The Hall array is differential, which cancels out the stray magnetic field. These sensors provide two power supply options (3.3V or 5V) and a wide current range for the best accuracy in different applications. Other features include adjustable bandwidth up to 100kHz, 4μs output rising time, and -40°C to +125°C operating temperature range. Typical applications for MPS MCS180x Linear Hall-Effect Current Sensors include motor controls, automotive systems, load detection and management, switch-mode power supplies, and overcurrent fault protection.

Resultados: 31
Seleccionar Imagen Número de referencia Fabr. Descripción Hoja de datos Disponibilidad Precio (EUR) Filtre los resultados de la tabla por precio unitario basándose en su cantidad. Cant. RoHS Modelo ECAD Valor de corriente Tipo de sensor Tiempo de respuesta Precisión Rango de frecuencia Voltaje operativo de suministro Tipo de salida
Monolithic Power Systems (MPS) Sensores de corriente montados en placa 5V Hall current sensor. 1.5% accuracy. 2.4kV Isolation 1.169En existencias
Mín.: 1
Múlt.: 1
Bobina: 500

50 A Current Sense 5 us 5 V Analog
Monolithic Power Systems (MPS) Sensores de corriente montados en placa 5V Hall current sensor. 1.5% accuracy. 2.4kV Isolation 764En existencias
Mín.: 1
Múlt.: 1
Bobina: 500

20 A Current Sense 5 us 5 V Analog
Monolithic Power Systems (MPS) Sensores de corriente montados en placa 5V Hall current sensor. 1.5% accuracy. 2.4kV Isolation 418En existencias
500Fecha prevista: 09/07/2026
Mín.: 1
Múlt.: 1
Bobina: 500

10.5 mA Current Sense 5 us 2.5 % 100 kHz 5 V Analog
Monolithic Power Systems (MPS) Sensores de corriente montados en placa 5V Hall current sensor. 2.5% accuracy. 200V Isolation 2.117En existencias
Mín.: 1
Múlt.: 1
Bobina: 2.500
12.5 A Current Sense 5 us 3 % 100 kHz 5 V Analog
Monolithic Power Systems (MPS) Sensores de corriente montados en placa 3.3V Hall current sensor. 1.5% accuracy. 2.4kV Isolation 1.108En existencias
Mín.: 1
Múlt.: 1
Bobina: 2.500

30 A Current Sense 5 us 3.3 V Analog
Monolithic Power Systems (MPS) Sensores de corriente montados en placa 5V Hall current sensor. 1.5% accuracy. 2.4kV Isolation 2.245En existencias
Mín.: 1
Múlt.: 1
Bobina: 2.500

5 A Current Sense 5 us 5 V Analog
Monolithic Power Systems (MPS) Sensores de corriente montados en placa 3.3V Hall current sensor. 2.5% accuracy. 200V Isolation 677En existencias
Mín.: 1
Múlt.: 1
Bobina: 500

10.5 A Current Sense 5 us 3 % 100 kHz 3.3 V Ratiometric
Monolithic Power Systems (MPS) Sensores de corriente montados en placa 3.3V Hall current sensor. 2.5% accuracy. 200V Isolation 287En existencias
Mín.: 1
Múlt.: 1
Bobina: 500

10.5 A Current Sense 5 us 3 % 100 kHz 3.3 V Ratiometric
Monolithic Power Systems (MPS) Sensores de corriente montados en placa 5V Hall current sensor. 2.5% accuracy. 200V Isolation 359En existencias
Mín.: 1
Múlt.: 1
Bobina: 500

25 A Current Sense 5 us 3 % 100 kHz 5 V Analog
Monolithic Power Systems (MPS) Sensores de corriente montados en placa 3.3V Hall current sensor. 1.5% accuracy. 2.4kV Isolation 329En existencias
500Fecha prevista: 08/07/2026
Mín.: 1
Múlt.: 1
Bobina: 500

5 A Current Sense 5 us 3.3 V Analog
Monolithic Power Systems (MPS) Sensores de corriente montados en placa 3.3V Hall current sensor. 1.5% accuracy. 2.4kV Isolation 42En existencias
10.000Pedido
Mín.: 1
Múlt.: 1
Bobina: 2.500

5 A Current Sense 5 us 3.3 V Analog
Monolithic Power Systems (MPS) Sensores de corriente montados en placa 3.3V Hall current sensor. 1.5% accuracy. 2.4kV Isolation 380En existencias
500Fecha prevista: 04/06/2026
Mín.: 1
Múlt.: 1
Bobina: 500

10 A Current Sense 5 us 3.3 V Analog
Monolithic Power Systems (MPS) Sensores de corriente montados en placa 3.3V Hall current sensor. 1.5% accuracy. 2.4kV Isolation 563En existencias
Mín.: 1
Múlt.: 1
Bobina: 500

40 A Current Sense 5 us 3.3 V Analog
Monolithic Power Systems (MPS) Sensores de corriente montados en placa 5V Hall current sensor. 1.5% accuracy. 2.4kV Isolation 430En existencias
Mín.: 1
Múlt.: 1
Bobina: 500

10 A Current Sense 5 us 5 V Analog
Monolithic Power Systems (MPS) Sensores de corriente montados en placa 5V Hall current sensor. 1.5% accuracy. 2.4kV Isolation 287En existencias
Mín.: 1
Múlt.: 1
Bobina: 500

40 A Current Sense 5 us 5 V Analog
Monolithic Power Systems (MPS) Sensores de corriente montados en placa 5V Hall current sensor. 2.5% accuracy. 200V Isolation 187En existencias
Mín.: 1
Múlt.: 1
Bobina: 500

12.5 A Current Sense 5 us 3 % 100 kHz 5 V Analog
Monolithic Power Systems (MPS) Sensores de corriente montados en placa 3.3V Hall current sensor. 1.5% accuracy. 2.4kV Isolation
1.970Fecha prevista: 20/03/2026
Mín.: 1
Múlt.: 1
Bobina: 2.500

20 A Current Sense 5 us 3.3 V Analog
Monolithic Power Systems (MPS) Sensores de corriente montados en placa 3.3V Hall current sensor. 2.5% accuracy. 200V Isolation No en almacén Plazo producción 18 Semanas
Mín.: 1
Múlt.: 1
Bobina: 2.500

8.5 mA Current Sense 5 us 3.3 V Analog
Monolithic Power Systems (MPS) Sensores de corriente montados en placa 3.3V Hall current sensor. 2.5% accuracy. 200V Isolation No en almacén Plazo producción 18 Semanas
Mín.: 2.500
Múlt.: 2.500
Bobina: 2.500

8.5 mA Current Sense 5 us 3.3 V Analog
Monolithic Power Systems (MPS) Sensores de corriente montados en placa 5V Hall current sensor. 2.5% accuracy. 200V Isolation No en almacén Plazo producción 18 Semanas
Mín.: 2.500
Múlt.: 2.500
Bobina: 2.500

25 A Current Sense 5 us 3 % 100 kHz 5 V Analog
Monolithic Power Systems (MPS) Sensores de corriente montados en placa 3.3V Hall current sensor. 1.5% accuracy. 2.4kV Isolation No en almacén Plazo producción 18 Semanas
Mín.: 1
Múlt.: 1
Bobina: 2.500

10 A Current Sense 5 us 3.3 V Analog
Monolithic Power Systems (MPS) Sensores de corriente montados en placa 3.3V Hall current sensor. 1.5% accuracy. 2.4kV Isolation Plazo producción 22 Semanas
Mín.: 1
Múlt.: 1
Bobina: 500

20 A Current Sense 5 us 3.3 V Analog
Monolithic Power Systems (MPS) Sensores de corriente montados en placa 3.3V Hall current sensor. 1.5% accuracy. 2.4kV Isolation No en almacén Plazo producción 22 Semanas
Mín.: 500
Múlt.: 500
Bobina: 500

30 A Current Sense 5 us 3.3 V Analog
Monolithic Power Systems (MPS) Sensores de corriente montados en placa 3.3V Hall current sensor. 1.5% accuracy. 2.4kV Isolation No en almacén Plazo producción 18 Semanas
Mín.: 2.500
Múlt.: 2.500
Bobina: 2.500

40 A Current Sense 5 us 3.3 V Analog
Monolithic Power Systems (MPS) Sensores de corriente montados en placa 3.3V Hall current sensor. 1.5% accuracy. 2.4kV Isolation No en almacén Plazo producción 22 Semanas
Mín.: 1
Múlt.: 1
Bobina: 500

50 A Current Sense 5 us 3.3 V Analog